Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
®
C US
XG0770 150105.1
R320
R420
R-Series
Indoor
Resi
dential
Fireplace
Installation & Maintenance Manual
IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
DANGER
Irritant
Cutting
Watch your step
Slippery floor
High temperatures
Glass hazard
Danger of suffocation
High voltage
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Oxidising
Danger of death
Biohazard
Laser Radiation
Danger of entrapment
Hot surface
General Warning
Blank
Gas bottles
Watch for
falling objects
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
radiation
Radiation
Hazardous to the
Environment
Danger of harming
your hands
Irritant
Cutting
Watch your step
Slippery floor
High temperatures
Glass hazard
Danger of suffocation
High voltage
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Oxidising
Danger of death
Biohazard
Laser Radiation
Danger of entrapment
Hot surface
General Warning
Blank
Gas bottles
Watch for
falling objects
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
radiation
Radiation
Hazardous to the
Environment
Danger of harming
your hands
Irritant
Cutting
Watch your step
Slippery floor
High temperatures
Glass hazard
Danger of suffocation
High voltage
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Oxidising
Danger of death
Biohazard
Laser Radiation
Danger of entrapment
Hot surface
General Warning
Blank
Gas bottles
Watch for
falling objects
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
radiation
Radiation
Hazardous to the
Environment
Danger of harming
your hands
Irritant
Cutting
Watch your step
Slippery floor
High temperatures
Glass hazard
Danger of suffocation
High voltage
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Oxidising
Danger of death
Biohazard
Laser Radiation
Danger of entrapment
Hot surface
General Warning
Blank
Gas bottles
Watch for
falling objects
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
NOTICE
If the information in these instructions is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
WARNING
This fireplace is certified to ANSI Z21.50 / CSA 2.22 Vented Fireplace Standard as a
power assisted direct vent fireplace. This product uses outdoor air for combustion and
and exhausts combustion products outdoors.
NOTICE
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - XG0770 150105.1

Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248®C USXG0770 150105.1 R320 R420 R-SeriesIndoor

Seite 2 - Table of Contents

Figure 3. Fireplace installation, (Rough Frame-In dimensions). Framing DimensionsModel Q R UR-Series R320* 55" 47"**23¾"†R-Series R420

Seite 3 - Safety Alert Key

Place the Fireplace on the platform and install the Vent pipe, and Power Vent module. Next, connect the Gas line, and provide a gas service shut-off v

Seite 4

Figure 5. Completed back frame Fireplace installationBack framing the Fireplace NOTE: Maintain a 1" clearance around the throat (projection at t

Seite 5

Picture of Non combustible HeaderRecessed Installation: This replace can be recessed into the oor to get the viewing area as low as possible.Mainta

Seite 6

Figure 7. Flue cover and collar removal, Top Vented replaceFigure 7a. Flue cover and collar installation, Rear Vented replaceR320 & R420 Powe

Seite 7

Figure 8. Factory installed Top Vent Pressure Sensing TubeFigure 8a. Supplied Rear Vent Pressure Sensing TubeFigure 9. Removal of Top Vent air baf

Seite 8

Figure 10. Straight Vertical, Top or Rear Vent, Roof mounted power vent. Figure 10a. Multi-Elbow, Top or Rear Vent, Roof mounted powe

Seite 9

Figure 10b. Multi-Elbow with downward vent run, Top or Rear Vent, Roof mounted power vent. Note: See Power Vent manual for installat

Seite 10 - Installation

Figure 12. Straight Horizontal, Top or Rear Vent, Wall mounted ... power vent. Figure 12b. Multi-Elbow, Top or Rear Vent, Wall moun

Seite 11

D** Figure 12c. Multi-Elbow with downward vent run, Top or Rear Vent, Wall mounted power vent. Note: See Power Vent manual for in

Seite 12

Page 2XG0770 - 150105.1Table of ContentsR320 & R420 Power Vent Indoor Gas FireplaceInstruction Manual ContentsIntroduction 3Safety Alerts 3Secti

Seite 13

The following components and associated Montigo part numbers are for installation of a roof or wall mounted Power Vent. Only use Montigo Vent Componen

Seite 14

Section 3-5: Heat Shields Installing a Wall Mounted RHS101 Heat shieldThe RHS101 Heat shield must be used if vent pipe passes through a wall or ceili

Seite 15

R320 & R420 Power Vent Indoor Gas FireplacePage 22XG0770 - 150105.1InstallationSection 4: WiringFigure 15. R320* / R420* Series Control Box / Po

Seite 16

Figure 15a. (Control Panel Overview)Figure 15b. R320 / R420 Control ModuleLeft-side View Right-side ViewFigure 15c. (Remote Switch Wire connection)Wa

Seite 17

115R1 R2 R3R1R2LightPVPlugPV Speed ControllerYellowYellowBlackBlueBlueBrownYellowBlueBlackWhiteWhite1234 5Combustion AirFlueGasWallSwitchOrangeWhiteBl

Seite 18

Figure 17. Gas Inlet Supply location.Fuel TypeVerify that your replace is compatible with your available gas type. Natural Gas or Propane shown by &q

Seite 19

Figure 18. LED Indicators If the red LED is illuminated (beside the fuse) you have power to the panel. If no LED, check fuse and replace with equall

Seite 20

As shown in Figure 19; Install the supplied Non-combustible cement board to overlap the new Horizontal & Vertical 2 x 4's, See Figure 5. Plac

Seite 21

Figure 20. Combustible mantles and facings. (Not to scale)Finishing Around the FireplaceNon-combustible mantels and mouldings may be safely inst

Seite 22 - (standard)

Section 8: Removing & Installing Screen and WindowRemoving the Screen:Follow the steps below to remove, or install the R320* / R420*Step 1: Prepar

Seite 23 - Installing the Remote Switch

Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas replace

Seite 24 - XG0770 - 150105.1

The R320* / R420* is supplied with glass restones. To install the restones remove the trim and door as shown in the previous section. Follow these i

Seite 25 - 1/2” MPT gas

TO TURN OFF GAS TO APPLIANCE: LIGHTING INSTRUCTIONS: FOR YOUR SAFETY - READ BEFORE LIGHTING : Heat Sensor / Conmustion A

Seite 26

General Have the replace and installation inspected yearly. The inspection must include, but is not limited to, the following: • A visual che

Seite 27 - Clearance required for

R320 & R420 Power Vent Indoor Gas FireplacePage 33XG0770 - 150105.1AppendixAppendix A: Power Vent LocationsFor installation instructions on this

Seite 28

Replacement PartsHoneywell HSI R320 R420NG Gas ValveRGC1004LP Gas ValveRGC1003

Seite 29

R320 & R420 Power Vent Indoor Gas FireplacePage 35XG0770 - 150105.1AppendixPVVEX58-300 Power Vent LocationsvvFIXEDCLOSEDOPERABLEFCBvvOPERABLEFIXE

Seite 30

R320 & R420 Power Vent Indoor Gas FireplacePage 36XG0770 - 150105.1AppendixFor installation instructions on this termination see instruction guid

Seite 31 - Operation

R320 & R420 Power Vent Indoor Gas FireplacePage 37XG0770 - 150105.1AppendixPVHEX58-300 Power Vent LocationsvvFIXEDCLOSEDOPERABLEFCBvvOPERABLEFIXE

Seite 32 - Maintenance

R320 & R420 Power Vent Indoor Gas FireplacePage 38XG0770 - 150105.1AppendixPV HFL58-300 Horizontal Power Vent DetailFront ViewEaves / Overhang W

Seite 33 - Not Acceptable

R320 & R420 Power Vent Indoor Gas FireplacePage 39XG0770 - 150105.1AppendixPVHFL58-300 Power Vent LocationsvvFIXEDCLOSEDOPERABLEFCBvvOPERABLEFIXE

Seite 34

Installation and repairs should be done by an authorized gas fireplace service technician. The appliance should be inspected before use and at least a

Seite 35 - Appendix

Note: There is enough clearance in the above clearances drawing to allow for a vanity ring to be added on at a later time.R320 & R420 Power Ven

Seite 36

R320 & R420 Power Vent Indoor Gas FireplacePage 41XG0770 - 150105.1AppendixPVHIN58-300 Inline Power Vent with TMHIN58-40 Termination vvFIXEDCLOSE

Seite 37

The WarrantyThe Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the M

Seite 38

Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.

Seite 39

XG0770 -150105.1R320 - R420Single Sided Gas Fireplace

Seite 40

Introduction to the R-Series Fireplace: The complete system will require a rebox, a power vent module, an electrical control panel, and a vent system

Seite 41

Rating Plate Sample 

Seite 42

Section 1: Product DimensionsFront ViewSide ViewTop ViewFigure 1. R320* Fireplace dimensions (Tolerance ± ⅛").Installation 4858"1237 14&qu

Seite 43 - Amendment

Figure 1a. R420* Fireplace dimensions (Tolerance ± ⅛").Front ViewSide ViewTop View 6058"1541 14"356 38"967 4714"1201 151

Seite 44 - R320 - R420

Frame in the enclosure for the unit with framing materials, see Figure 3.NOTE: When constructing the framed opening, please ensure there is access to