Page 7
XG0816 - 150204.1
H*38DF PFC Peninsula Gas Fireplace
Installation
Section 2: Framing
Note: Images are shown without screens for clarity purposes. However,
your replace should not be operated without proper installation of
screens.
1). Frame in the enclosure for the unit with framing materials. The
framed opening for the assembled replace is 23 3/4" wide, x 44"
high x 41" deep, see Figure 2
.
NOTE: When constructing the framed opening, please ensure there is
access to install the gas line when the unit is installed. See Figure 21
Figure 2� Framing dimensions.
Figure 3� Combustible Framing for shelves over the replace, Rear vent.
Figure 5� Non Combustible Framing with alcove above replace, Top Vent.
41
23 3/4
44
Figure 4� Combustible Framing for shelves over the replace, Top vent.
11”
Min.
Combustible Shelf
33”
44”
Exterior
Wall
Combustible Header
12” Max.
4” Nailing flange
or Non-combustible
material.
46” Min
17 1/2”
2” Min.
44”
Combustible Shelf
Combustible Header
Min.
Exterior
Wall
PEL Short
90 elbow
4” Nailing flange
or Non-combustible
material.
58” Min for HP
Floor
39 5/8”
44”
Combustible
Header
Min. 1
2”
Ceiling level
Non-Combustible
Header
Non-Combustible
materials. Alcove
over fireplace.
Top Vent
Non-Combustible
Materials, with Low
profile mantel / Alcove
over fireplace.
84”
min.