XG0147 - 150204.1
H*38DF Gas Fireplace
Installation
6”
Clearances
When installing a shelf over the top of the replaces, the following
guidelines must be adhered to:
For Rear Vent applications, the minimum clearance is 2" from the rear
of the replace to a wall, or any combustible materials, and 9" clearance
from the top of the replace to the underside of any combustible shelf
materials.
For Top Vent applications, the minimum clearance is 2" from the rear of
the replace to a wall, or any combustible materials, and 17 1/2" to the
underside of any combustible shelf materials, Figure 4.
For Top or Rear Vent applications where the Minimum height is required
above the replace, (for an alcove or low prole shelf), ALL Materials
MUST BE NON-COMBUSTIBLE, Figure 5. The minimum clearance is
2" from the rear of the replace to a wall, or any combustible materials.
1” clearance is maintained on sides and bottom of vent runs and 2”
above horizontal vent runs to any combustible material.
The replace clearances are shown below:
H*38DF 9 17 1/2 2 1 0 See Section 6:
Finishing around
the replace
HW38DF 9 17 1/2 3 1 0
MODEL
Top - Rear Vent
Installing The Standoffs
To avoid elevated mantel temperatures, all H*38DF* gas
replaces are required to have the supplied standoffs installed.
The replace is supplied with two standoffs. Bend and install these
standoffs on top of the replace ensuring that the height of the standoff
maintains a 6" clearance.
Figure 6. Installing the standoff's.
Figure 7. Installing the Nailing Flange Extension.
Installing the Nailing Flange Extension
Once the replace is placed into the rough framed opening, the supplied
Nailing Flange Extension (Part No. H38074) must be fasten securely
into place, with nails or wood screws. as shown in Figure 7.
Note: The nailing ange extension can be substituted with a piece of
NON-Combustible material of the same size and thermal characteristics,
ie: cement board or equivalent. This is recommended in applications
where the facing materials will not adhere to the metal nailing ange.
6"
Note: Clearance from top of replace to a ceiling within the replace
enclosure.
Top - Top Vent
Rear
Sides
Floor
Mantel