Follow the instructions for the unit installation in the up to Step 1 on
Page 7 of the installation guide.
The unit is in place with the screws removed as illustrated there.
49.25
28.12 16.56
37.69
40.94
19.80
2.90
IOSK3-A03
IOSK3-A02
IOSK3-A01
320-368
STEP 1: Back frame the unit with the metal header supplied by Montigo
above the unit and either combustible or non-combustible framing to the
sides and bottom maintaining clearances as shown and ensuring the
gallvanized apron (Fig 1, Part No. 320-368) can be attached to the framing.
Figure 1: Indoor/ Outdoor Sealing Kit Ccmponents
Figure 2: Backframe unit
CLEARANCE TO COMBUSTIBLES:
6" Top, 3" each side, 3" bottom from the protruding window box.
Figure 3: Attach galvanized apron to unit
STEP 4: Attach the stainless steel frame (Fig. 1, Part No. IOSK3-A01)
to the galvanized frame lining up the holes around perimeter. Secure in
place through holes across the top and down the sides. Do not secure
the bottom ange.
STEP 5: Apply approved waterproong membrane over the ange of
the frame on the top and sides and under the ange of the frame at
the bottom. The membrane should overlap the frame approximately 2"
around the perimeter.
STEP 6: All facing materials may now be installed over the frame.
BE CERTAIN TO MAINTAIN 6" ABOVE AND 3" ON SIDES AND BOTTOM
TO ANY COMBUSTIBLE MATERIAL
STEP 2: Place the galvanized apron and attach to the unit using the 6
screws removed from the unit face, Figure 3.
STEP 7: Mount the framed glass (Fig 1, IOSK3-A02) onto the unit and
secure in place rst with only the two side screws.
STEP 8: Place the Galvanized strips (4 supplied) at each corner lining up
screw holes and secure both the strips and the framed glass to the unit.
STEP 9: Attach the stainless steel trim (Fig1, IOSK3-A03), by placing it
on and ensuring the magnets catch the previously placed galvanized strip.
Figure 4: Install silicone gasket
STEP 3: Install the silicon gasket material (supplied by Montigo) in one
continuous strip with the joint at the bottom, Figure 4.
Indoor / Outdoor Sealing Kit For R320 ST
Use this instruction in conjuction with unit
instruction manual (Doc. XG0772)
Installation Instruction
Kit Part No. IOSK3
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Kit Part No. IOSK3

Follow the instructions for the unit installation in the up to Step 1 on Page 7 of the installation guide.The unit is in place with the screws removed

Seite 2

IOSK 320 Instructions Cont'd49.2528.12 16.5637.6940.9419.802.90IOSK3-A03IOSK3-A02IOSK3-A01320-368